COMMAND
locatecage
DESCRIPTION
The locatecage command allows system administrators to locate a drive cage, drive
magazine, or port in the system using the devices’ blinking LEDs.
SYNTAX
The syntax for the locatecage command can be one of the following:
To locate an entire drive cage:
locatecage [option <arg>] <cage_name>
To locate a drive magazine:
locatecage [option <arg>] <cage_name> <mag>
To locate a port:
locatecage [option <arg>] <cage_name> <port_name>
AUTHORITY
Super, Service
OPTIONS
–t <sec>
Specifies the number of seconds, from 0 through 255 seconds, to blink the LED. If the
argument is not specified, the option defaults to
60 seconds.
SPECIFIERS
<cage_name>
Specifies the drive cage name as shown in the Name column of showcage command
output.