3PAR InFormĀ® OS 2.2.4 MU6/MU7 P14 Release Notes (320-200276 Rev A, January 2011)
4
Release 2.2.4 MU6/MU7 P14 Release Notes InForm OS Version 2.2.4
4.0 Modifications to the InForm OS
The following items have been addressed in this release.
Bug ID Item Description
56044 An error in the
firmware
database caused
750GB NL hard drive
upgrades to fail.
A typo existed in the firmware database and
referenced a nonexistent file. As a result, 750GB NL
hard drives in DC3 failed to upgrade because the
system attempted to download a nonexistent file.
Error corrected in the firmware database.
58751 Drives cannot be
admitted to the InServ
after upgrading the
Hitachi 2TB drive
firmware from A3EA
to A3GG firmware.
The A3GG firmware packaged with 2.2.4 P13 had
resulted in an incorrect setting of BR-2401. This
caused the drive to use a WWN generated by the
bridge and was reset or power cycled. The bridge
generated WWN does not change if the drive was
replaced and thus will not allow the drive to be
admitted.