22.9
InForm OS Version 2.2.4 Command Line Interface Reference
The columns in the previous example are identified as follows:
Node. The controller node number.
PS. The power supply number.
Bat. The battery ID.
Serial. The battery serial number.
State. The current status of the battery. Battery states can be as follows:
--. Cannot determine the battery state.
NotPresent. Battery is missing.
OK. Battery is operating normally.
Failed. Battery is operating abnormally.
MaxLifeLow. Maximum battery life is low (less than 12 minutes).
ExpDate. The expiration date of the battery.
Expired. Indicates whether expired batteries are connected to the power supply.
Testing. Indicates whether a battery test is in progress. When a battery test is in progress,
the batteries cannot be counted so the number of batteries shown is a cached value.
The following example displays detailed battery information:
cli% showbattery -d
--------------Node 0 PS 0 Battery 0---------------
Node ID : 0
Power Supply ID : 0
Battery ID : 0
Manufacturer : MAG
Model : 0800-0016-50.0B
Serial Number : 70315366
State : OK
Charge State : FullyCharged
Charge Level(%) : 100
Max Battery Life(mins) : 25
Expired : No
Test in Progress : No
Expiration Date : 2010-07-17 13:00:00 PD
...
ChgLvl. Percentage of battery charge status for the node.