3PAR InForm Operating System 2.3.1 Release Notes (320-200178 Rev D, May 2010)

2.20
3PAR InForm Operating System Release Notes InForm OS Version 2.3.1
43868 InForm Management Console
falsely reports both controller nodes
as degraded.
The power supply OK events were mishandled
by the system manager, which led to the
InForm Management Console receiving
degraded status instead of OK status.
43967 System manager segmentation fault
during chunklet relocation.
The code has been modified so that releasing
the mutex is done before freeing the memory
that points to the mutex.
44384 Backported SSH security fixes not
reported as fixed.
Several backported security bug fixes have
been previously applied to the version of SSH
running on the system. Some security scanners
report this as a possible vulnerability.
The version of SSH used has been upgraded to
5.1p1.
45225 The System Manager does not treat
device types FC (rpm 10) and FC_15
(rpm 15) the same way.
When the command showsys -space was
issued, the System Manager looked for the
device type of FC information and found
nothing because the base volume was created
using FC_15 disks.
For the showsys -space command the System
Manager now converts the internal device
types FC (rpm10) and FC_15 (rpm 15) to the
external device type FC. Volumes created on
both types of FC devices will now be accounted
for.