3PAR InForm® Management Console 4.1.1 P01 Release Notes 3PAR Inc.
Changes The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, 3PAR Inc. assumes no liability resulting from errors or omissions in this document or from the use of the information contained herein. 3PAR reserves the right to make changes in the product design without reservation and without notification to its users.
InForm Management Console 4.1.1 P01 Release Notes 1.0 Modifications to the InForm Management Console The following items have been addressed in this release. Bug ID Item Description 58735 Class cast exception on Occurs when selecting the volume tree node in the Layout Layout Grid volume Grid manager. The volume table in the Layout Grid panel manager does not show any volume.
InForm Management Console 4.1.1 P01 Release Notes 2.0 Known Issues with the InForm Management Console Bug ID Item Description 46452 An IMC fatal error occurs when An IMC fatal error occurs when a rolling performing a rolling upgrade upgrade is performed on the InServ. Workaround: When performing an InServ rolling upgrade, it is recommended that all IMC instances that are connected to that InServ be shut down.
InForm Management Console 4.1.1 P01 Release Notes 53508 Remote Copy group commands When Remote Copy Disaster Recovery should not be enabled when operations are executed, tasks are created on Disaster Recovery tasks are in the InServ, since the command(s) can take a progress while to execute. During that time, other Remote Copy group operations (start, stop, etc.) should not be executed.
InForm Management Console 4.1.