44409 The amount of consumed
memory continues to grow.
If the IMC is connected to many InServs and is
left running for days, the IMC may eventually
run out of memory and will need to be
restarted. This is because the JVM is not
releasing memory back to the operating system
even though garbage collection has occurred
and the IMC is not using all the memory
allocated by the JVM.
Workaround: Stop and restart the IMC
application before reaching this out of memory
condition.
46372 Drive cage displays do not
correctly report degraded SFPs.
For an unqualified SFP, the drive cage SFPs table
show the State of the SFP as Normal, but
should show Degraded.
Workaround: Select a row of the drive cage
SFPs table to see the detail page. If the
Qualified field shows No, then it is an
unqualified SFP and its state should be deemed
as Degraded.
46452 An IMC fatal error occurs when
performing a rolling upgrade.
An IMC fatal error occurs when a rolling
upgrade is performed on the InServ.
Workaround: When performing an InServ
rolling upgrade, it is recommended that all IMC
instances that are connected to that InServ be
shutdown.