3PAR AIX Implementation Guide (320-200187, June 2011)
3.6
Installing 3PAR MPIO on the AIX Server (Local Boot Internal)
3PAR AIX 5.3, 6.1, and 7.1 Implementation Guide
3PAR Confidential
Please refer to 3PAR MPIO v2.2 for IBM AIX for upgrade and removal instructions.
3.3.2 Displaying the Path Status After Installing 3PAR MPIO
After the installation of the 3PAR MPIO for AIX HBA, check path status and verify the
connection between the host server and InServ Storage Server.
■ To display the FC device available on the AIX host, issue lsdev -Cc disk.
■ To display the path status through the AIX CLI on hdisk1, issue lspath –l hdisk1:
■ To display the specific path information on hdisk1, issue lspath -l hdisk1 -F
“status name parent connection”
.
# lsdev -Cc disk
hdisk0 Available 00-08-00 SAS Disk Drive
hdisk1 Available 07-00-01 3PAR InServ Virtual Volume
hdisk2 Available 07-00-01 3PAR InServ Virtual Volume
hdisk3 Available 07-00-01 3PAR InServ Virtual Volume
hdisk4 Available 07-00-01 3PAR InServ Virtual Volume
hdisk5 Available 07-00-01 3PAR InServ Virtual Volume
# lspath -l hdisk1
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi4
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
Enabled hdisk1 fscsi5
NOTE: Highlighted text shows the details for node, slot, and port (n:s:p).