3PAR AIX Implementation Guide (320-200187, June 2011)
2.3
Configuring the InServ Storage Server Running InForm OS 2.3.X
3PAR AIX 5.3, 6.1, and 7.1 Implementation Guide
3PAR Confidential
2.1 Configuring the InServ Storage Server Running InForm OS 2.3.X
This section describes how to configure InServ Storage Server ports running OS 2.3.X.
2.1.1 Configuring Ports for a Direct Connection
To configure the InServ Storage Server ports for a direct connection, complete the following
steps.
1 To set up the InServ Storage Server ports for a direct connection, issue the following set of
commands with the appropriate parameters for each direct connect port:
a
controlport offline [node:slot:port]
b controlport config host –ct loop [node:slot:port]
where -ct loop specifies a direct connection.
c
controlport rst [node:slot:port]
Example:
REQUIRED: The following setup must be completed before connecting the InServ
Storage Server port to a device.
# controlport offline 1:5:1
# controlport config host -ct loop 1:5:1
# controlport rst 1:5:1