HP 3PAR VMware ESX Implementation Guide
Figure 7 Adding an iSCSI Target
8. Click Ping to verify connectivity.
9. After a successful ping, click Save/Login.
10. When both controllers are configured, use the showiscsisession command to display the
iSCSI sessions on the HP 3PAR StoreServ Storage and the host. If everything is configured
correctly, the output should be similar to the following example:
root@jnodec103140:S99814# showiscsisession
0:2:1 10.101.0.100 21 15 1 iqn.1990-07.com.emulex:a0-b3-cc-1c-94-e1 2012-09-24 09:57:58 PDT
1:2:1 10.101.1.100 121 15 1 iqn.1990-07.com.emulex:a0-b3-cc-1c-94-e1 2012-09-24 09:57:58 PDT
root@jnodec103140:S99814# showhost -d Esx50Sys1
1 Esx50Sys1 VMware iqn.1990-07.com.emulex:a0-b3-cc-1c-94-e1 0:2:1 10.101.0.100
1 Esx509Sys1 VMware iqn.1990-07.com.emulex:a0-b3-cc-1c-94-e1 1:2:1 10.101.1.100
11. If you do not want to use CHAP as an authentication method, exit the CN1100E setup screens
and reboot.
If you want to use CHAP as an authentication method, return to the Add/Ping iSCSI Target
screen as shown in ???, select Authentication Method, and then choose one of the following
options:
• Select One-Way CHAP (see ???).
24 Configuring the HP 3PAR StoreServ Storage for iSCSI