HP 3PAR Service Processor Software 2.5.x Release Notes (QR482-96663)
DescriptionItemIssue ID
Previously, if a disk cage disk replacement script is aborted or otherwise
improperly closed, a subsequent use of the Guided Maintenance disk
Fixed issues with aborted
disk replacements scripts
56796
replacement scripts may show erroneous data left over from the previous
run. This is now fixed.
in the Guided
Maintenance
A Locate Node feature has been added for E-Class, F-Class, S-Class, T-Class
Storage Systems for node operations (ex. replace DIMMs and adapters).
The feature flashes node LEDs to assist with node identification.
Locate Node feature
added for E-Class,
F-Class, S-Class, T-Class
Storage Systems
54195
Update password handling code to accept & as a valid character when
creating a user password in SPOCC.
The & is now an accepted
character in user
passwords
54047
The SPevent now attempts to connect 3 times before giving up on gathering
events.
The SPevent performs
multiple attempts before
issuing an Alert
52386
Provide information on the process which is holding the lock on a Health
Check, if a lock cannot be allocated.
Display who is holding the
lock if Check Health
cannot be run
52055
When performing a Health Check via the SPMAINT a message of: The System
is Healthy will be displayed if this is the case, rather than displaying a blank
message.
The Health Check displays
System is Healthy
51246
Install the keys required to verify the authenticity of RPM packages.Install Appropriate Keys
for Package Validity
38421
Known Issues with the Service Processor
The Hot Fixes Link is Invalid for Customer Accounts (Issue 64357)
The Hot Fixes link from the Support menu is not activated for customers. Customers clicking the link
will be led back to the Support menu.
HP P10000 3PAR Storage Systems do not support iSCSI - FCoE Adapter Replacement
in the Guided Maintenance (Issue 63812)
Initial shipments of the HP P10000 3PAR Storage System do not support an iSCSI - FCoE adapter
replacement. The SP 2.5.1 software version of Guided Maintenance lists an iSCSI - FCoE replacement
operation, but it is not supported and should not be used.
FC-AL Replacement for S-Class Storage Systems with DC2 Cages (Issue 63798)
If you are using the Guided Maintenance scripts to replace a DC2 FC-AL on an S-Class Storage
Systems, note that you must transfer and reuse the old SFPs from the failed FC-AL to the new FC-AL.
Poll: Protocol Failure Message During InSplore (Issue 63537)
In situations where the storage system is maximized, this message may be displayed while gathering
data for the InSplore. In these instances, the data being gathered at that time may not be complete.
SPOCC Does Not Support CLI Commands Requiring Confirmation (Issue 63435)
SPOCC provides a web interface to issue raw storage system CLI commands. However, SPOCC
does not support issuance of raw CLI commands (such as systemshutdownnode) that require
confirmation.
8 Service Processor Software 2.5.1 Release