IMPORTANT 3Gb SAS BL Switch Zoning Requirements
For the c7000 BladeSystem enclosure, use the following table to determine which external storage
enclosures to use when zoning the external storage to the server blades. For example, as shown in
the table, if a full-height server blade is installed in device bay 1-8 of a c7000 enclosure, and the
P700m Controller is installed in server mezzanine slot 2; the 3Gb SAS BL Switch must be installed in
BladeSystem interconnect bay 5, 6, 7, or 8 and it should be assigned a zone group that is in an
external storage enclosure attached to 3Gb SAS BL Switch ports 1, 2, 3, or 4.
Zone groups
must be in stor-
age
nl
enclosures
nl
connected to
these 3Gb SAS
BL Switch ports
BladeSystem
nl
c-Class
nl
interconnect bay
BladeSystem
nl
c-Class
nl
device bay
Mezzanine
nl
slot
Server typeBladeSystem
nl
c-Class
nl
enclosure
nl
model
1 – 43/41 – 8
1
Half height
c7000
5 – 83/49 – 16
1 – 45/6/7/81 – 8
2
5 – 85/6/7/89 – 16
1 – 43/4Any1
Full height 1 – 45/6/7/8Any2
5 – 85/6/7/8Any3
1 – 45/61A – 8A
Any
Half height
nl
Double dense
nl
(BL2x220c)
1 – 47/81B – 8B
5 – 85/69A – 16A
5 – 87/89B – 16B
1 – 43/4Any1
Full height
nl
Double wide
nl
(BL680c G7)
1 – 45/6/7/8Any2
5 – 85/6/7/8Any3
1 – 45/6/7/8Any4
5 – 83/4Any5
5 – 85/6/7/8Any7
For more information about cabling and zoning, see the HP Direct-Connect External SAS Storage for
HP BladeSystem Solutions Deployment Guide or HP 3G Virtual SAS Manager User Guide, available
on the BladeSystem Interconnects page of the HP Manuals website:
nl
http://www.hp.com/support/manuals.