IMPORTANT 3Gb SAS BL Switch Zoning Requirements

IMPORTANT
3Gb SAS BL Switch Zoning Requirements
The following tables show the interdependencies of components in an HP BladeSystem c-Class solution
that includes an HP StorageWorks 3Gb SAS BL Switch connected to external SAS storage enclosures.
Failure to follow these guidelines will result in an unsupported configuration.
For the c3000 BladeSystem enclosure, use the following table to determine which external storage
enclosures to use when zoning the external storage to the server blades. For example, as shown in
the table, if a full-height server blade is installed in device bay 1-8 of a c3000 enclosure, and the
P700m SAS Controller is installed in server mezzanine slot 2; the 3Gb SAS BL Switch must be installed
in BladeSystem interconnect bay 3 or 4 and it should be assigned a zone group that is in an external
storage enclosure attached to 3Gb SAS BL Switch ports 1, 2, 3, or 4.
Zone groups must
be in storage
nl
enclosures
nl
connected to these
3Gb SAS BL
Switch ports
BladeSystem
nl
c-Class
nl
interconnect
bay
BladeSystem
nl
c-Class
nl
device bay
Mezzanine
nl
slot
Server typeBladeSystem
nl
c-Class
nl
enclosure
nl
model
1 43/4Any2Half height
c3000
1 43/4Any2
Full height
5 83/4Any3
1 43/41A 8AA-sideHalf height
nl
Double dense
nl
(BL2x220c)
5 83/41B 8BB-side
1 43/4Any2
Full height
nl
Double wide
nl
(BL680c G7)
5 83/4Any3
5 83/4Any4
1 43/4Any7
*532321-002*