Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)
80 Fabric OS Documentation Addendum
53-1001216-01
Chapter 3, FE MIB Objects
4
Chapter 3, FE MIB Objects
Under the heading “FE MIB Overview” on page 215, add the following column to Table 6.
Under the heading “Definitions for FIBRE-CHANNEL-FE-MIB” on page 222, add the following row to
Table 7.
Under the heading “fcFeModuleFxPortCapacity 1.3.6.1.2.1.75.1.1.4.1.6” on page 233, add the
following to the existing list:
Brocade 8000 14 ports
Chapter 4, Entity MIB Objects
Under the heading “entPhysicalTable 1.3.6.1.2.1.47.1.1.1” on page 456, add the following row to
Table 11.
Under the heading “entPhysicalClass 1.3.6.1.2.1.47.1.1.1.1.5” on page 464, add the following
information:
Brocade 8000 switch can have the following hierarchy of physical objects:
• Chassis: One entry (one row)
• Container: One entry for each FRU slot (one switch blade, two power supplies, three fans)
• Module: 1 entry for switch blade, up to two entries for power supplies, and up to three entries
for fans.
Chapter 5, SW-MIB Objects
Under the heading “swAdmStatus 1.3.6.1.4.1.1588.2.1.1.1.1.8” on page 534, update the following
information to include 8000:
For the Brocade 3250, 3850, 3900, 8000, 24000, 48000 and DCX director the testing (3), faulty
(4) values are not applicable.
TABLE 2 FE MIBs and supported Fabric OS versions
MIB v6.1.2_cee
FIBRE-CHANNEL-FE-MIB (MIB-II branch) Yes
FCFABRIC-ELEMENT-MIB (experimental branch) No
TABLE 3 FIBRE-CHANNEL-FE-MIB Definitions
Type Definition Value Description
fcfeModuleFxPortCapacity Integer from 1 to 384 Maximum number of Fx_Ports within a module.
For the Brocade 8000, this value is 14.
TABLE 4 entPhysicalTable Entries for Brocade Switches
Platform Blades Fans Power Supply WWN Card
Brocade 8000 1 3 FRUs 2 PS 1 WWN unit