Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)

70 Fabric OS Documentation Addendum
53-1001216-01
New chapter, ZEUS System Messages
3
Severity WARNING
New chapter, ZEUS System Messages
A new chapter titled ZEUS System Messages was added after the WEBD System Messages chapter
and before the ZOLB System Messages; it contains all the new messages for the new feature, Zeus
driver module.
ZEUS-1001
Message <timestamp>, [ZEUS-1001], <sequence-number>,, ERROR, <system-name>, Port <port
number> port fault. Please change the SFP or check cable.
Probable Cause Indicates a deteriorated small form-factor pluggable (SFP), an incompatible SFP pair, or a faulty
cable between peer ports.
Recommended
Action
Verify if you are using a compatible SFPs on the peer ports. Determine whether the SFPs have
deteriorated and the Fibre Channel cable is faulty. Replace the SFPs or cable if necessary.
Severity ERROR
Modified messages
The following message has been modified in the chapter, C2 System Messages on page 70.
C2-1005
Message Message <timestamp>, [C2-1005], <sequence-number>,, ERROR, <system-name>, Rate
limit configuration is not effective on S(<slot number>) user port <port number>
because QoS license is not present.
Probable Cause Indicates that the switch does not have the QoS license added. Rate Limit is a licensed feature and
requires QoS license.
Recommended
Action
No action is required.
Severity ERROR
Deleted messages