Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)

62 Fabric OS Documentation Addendum
53-1001216-01
NSM-1005
3
Recommended
Action
No action is required.
Severity INFO
NSM-1005
Message <timestamp>, [NSM-1005], <sequence-number>,, INFO, <system-name>,The FCoE VLAN:
<Vlan name> is in use. First remove all the FCoE sessions of its member ports and
then try again to disable it.
Probable Cause Indicates that the FCoE VLAN is used in FCoEd.
Recommended
Action
Disable FCoE VLAN by removing all the FCoE sessions from its member ports.
Severity INFO
NSM-1006
Message <timestamp>, [NSM-1006], <sequence-number>,, INFO, <system-name>, FCoE on VLAN:
<Vlan name> has been disabled successfully.
Probable Cause Indicates that the FCoE is disabled on the VLAN.
Recommended
Action
No action is required.
Severity INFO
New chapter, ONM System Messages
A new chapter titled ONM System Messages was added after the NSM System Messages chapter
and before the PDM System Messages; it contains all the new messages for the new feature,
Operation, Administration and Maintenance module.
ONMD-1001
Message <timestamp>, [ONMD-1001], <sequence-number>,, ERROR, <system-name>, Feature
Mismatch: <feature>.
Probable Cause Indicates the content of a specific feature does not match with the link partner.
Recommended
Action
Change the setting for that feature on both ends to match them.
Severity ERROR