Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)
Fabric OS Documentation Addendum 59
53-1001216-01
L2SS-1057
3
L2SS-1057
Message <timestamp>, L2SS-1057], <sequence-number>,, ERROR, <system-name>,EXM table on
chip <chip_id> is 90 percent full
Probable Cause Indicates that the exact match table on the chip is 90% full.
Recommended
Action
No action is required. L2SYS will start learning the entries.
Severity INFO
New chapter, LACP System Messages
A new chapter titled LACP System Messages was added after the L2SYS System Messages chapter
and before the LOG System Messages; it contains all the new messages for the new feature, Link
Aggregation Control Protocol module.
LACP-1001
Message <timestamp>, [LACP-1001], <sequence-number>,, ERROR, <system-name>, <module>
Error opening socket (<error>).
Probable Cause Indicates that the initialization of a module within the LACP daemon has failed.
Recommended
Action
Download a new firmware version using the firmwareDownload command. Refer to the Fabric OS
Command Reference Manual for more information on this command.
Severity ERROR
New chapter, MSTP System Messages
A new chapter titled MSTP System Messages was added after the MS System Messages chapter
and before the NBFS System Messages; it contains all the new messages for the new feature,
Multiple Spanning-tree Protocol modules.
MSTP-1001
Message <timestamp>, [MSTP-1001], <sequence-number>,, ERROR, <system-name>, <msg>:<msg>.
Probable Cause Indicates that the system has failed to allocate memory.
Recommended
Action
Check the memory usage on the switch using the memShow command.
Restart or power cycle the switch.
Severity ERROR