Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)
58 Fabric OS Documentation Addendum
53-1001216-01
L2SS-1053
3
L2SS-1053
Message <timestamp>, L2SS-1053], <sequence-number>,, ERROR, <system-name>,NSM : Recv
bridge port conf Bridge: <name> No. of if <num>
Probable Cause Indicates that the L2SYS has received a bridge port conf notification from Network Service
Manager (NSM).
Recommended
Action
No action is required.
Severity INFO
L2SS-1054
Message <timestamp>, L2SS-1054], <sequence-number>,, ERROR, <system-name>,FDB error:
Error in creating AVL tree.
Probable Cause Indicates that the l2sys has encountered an error while initializing an AVL tree.
Recommended
Action
Restart or power cycle the switch.
Severity ERROR
L2SS-1055
Message <timestamp>, L2SS-1055], <sequence-number>,, ERROR, <system-name>,FDB error: L3SS
updation of moving MAC <Mac address> to new ifindex <ifindex> failed
Probable Cause Indicates that the l2sys has encountered an error while updating the Forwarding or Filtering Data
Base (FDB).
Recommended
Action
Restart or power cycle the switch.
Severity ERROR
L2SS-1056
Message <timestamp>, L2SS-1056], <sequence-number>,, ERROR, <system-name>,EXM table on
chip <chip_id> is 95 percent full
Probable Cause Indicates that the exact match table on the chip is 95% full.
Recommended
Action
Clear some of the entries, or wait till old entries age out.
Severity INFO