Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)

Fabric OS Documentation Addendum 37
53-1001216-01
ESW-1003
3
Probable Cause Indicates that the device is not present in the authorized profile list.
Recommended
Action
Verify that the device is authorized to log in to the switch. If the device is authorized, first run the
secPolicyDump command to verify whether the specified device world wide name (WWN) is listed. If
it is not listed, run the secPolicyAdd command to add this device to an existing policy.
Severity INFO
ESW-1003
Message <timestamp>, [ESW-1003], <sequence-number>,, ERROR, <system-name>, Slot ENABLED
but Not Ready during recovery, disabling slot = <slot number>(<return value>).
Probable Cause Indicates that the slot state has been detected as inconsistent during failover or recovery.
Recommended
Action
On a Brocade 8000 switch, restart or power cycle the switch.
Severity ERROR
ESW-1004
Message <timestamp>, [ESW-1004], <sequence-number>,, ERROR, <system-name>,Blade attach
failed during recovery, disabling slot = <slot number>.
Probable Cause Indicates that the blade has failed during failover or recovery.
Recommended
Action
On a Brocade 8000 switch, restart or power cycle the switch.
Severity ERROR
ESW-1005
Message <timestamp>, [ESW-1005], <sequence-number>,, ERROR, <system-name>,Diag attach
failed during recovery, disabling slot = <slot number>.
Probable Cause Indicates that the Diag blade attach command has failed during failover or recovery.
Recommended
Action
On a Brocade 8000 switch, restart or power cycle the switch.
Severity ERROR