Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)

36 Fabric OS Documentation Addendum
53-1001216-01
CCFG-1008
3
CCFG-1008
Message <timestamp>, [CCFG-1008], <sequence-number>,, ERROR, <system-name>, CMSH init
failed: <message>.
Probable Cause Indicates that the CMSH initialization has failed.
Recommended
Action
No action is required.
Severity ERROR
CCFG-1009
Message <timestamp>, [CCFG-1009], <sequence-number>,, INFO, <system-name>, Successfully
copied to <destination>.
Probable Cause Indicates that the file has been successfully copied to the destination.
Recommended
Action
No action is required.
Severity INFO
New chapter, ESWCH System Messages
A new chapter titled ESWCH System Messages was added after the ESS System Messages chapter
and before the EVMD System Messages; it contains all the new messages for the new feature,
Ethernet switch module.
ESW-1001
Message <timestamp>, [ESW-1001], <sequence-number>,, ERROR, <system-name>, Switch is not
in ready state - Switch enable failed switch status= 0x<switch status>, c_flags =
0x<switch control flags>.
Probable Cause Indicates that the switch enable has failed.
Recommended
Action
If the message persists, run the supportFtp command (as needed) to set up automatic FTP
transfers; then run the supportSave command and contact your switch service provider.
Severity ERROR
ESW-1002
Message <timestamp>, [ESW-1002], <sequence-number>,, INFO, <system-name>, Security
violation: Unauthorized device <wwn name of device> tries to flogin to port <port
number>.