Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)
Fabric OS Documentation Addendum 29
53-1001216-01
Chapter
3
Fabric OS Message Reference
In this chapter
The updates in this chapter are for the Fabric OS Message Reference, part number:
53-1000600-03.
Replace and update the chapters as described in the following sections:
•Updates to chapter 1, Introduction to System messages. . . . . . . . . . . . . . . 29
•New chapter, ANV System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
•New chapter, CEE CONFIG System Messages . . . . . . . . . . . . . . . . . . . . . . . . 34
•New chapter, ESWCH System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
•New chapter, FCOE System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
•New chapter, HSL System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43
•New chapter, L2SYS System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
•New chapter, LACP System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
•New chapter, MSTP System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
•New chapter, NSM System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
•New chapter, ONM System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
•New chapter, RMOND System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . 63
•New chapter, SSM System Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64
•New chapter, ZEUS System Messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
•Modified messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
•Deleted messages. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
Updates to chapter 1, Introduction to System messages
The “Reading a RAS system message” section has been modified to include new message formats.
This section provides information about reading system messages.
The following example shows the format of the RAS system error message:
<timestamp>, [<Event ID>], <Sequence Number>, <Flags>,<Severity>,<Switch
name>, <Event-specific information>
The following example shows a sample message from the error log:
2009/02/10-14:18:04, [SS-1000], 88, SLOT 6 | FFDC | CHASSIS, INFO, ESNSVT_DCX,
supportSave has uploaded support information to the host with IP address
168.159.16.128