Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)

18 Fabric OS Documentation Addendum
53-1001216-01
systemVerification
2
are not specified, the run uses the previously stored values. This option does
not perform a burninErrClear operation prior to starting the testing.
-short Sets the burn-in parameters that control the number of frames to 1. The
primary use for this command is software regression testing, or quick
validation that all hardware is operational. The shorter test cycle does not
have enough time to detect intermittent errors. This option performs a
burninErrClear operation prior to starting the testing operation.
-unit id Tests a single FRU in the system. The unit ID is the slot number of the blade
to be tested. On fixed port-count products, this parameter is not required.
Examples To initiate a short system verification test:
switch:admin> systemverification -short
systemverification: Setting parameters for short run.
systemverification: burnin parameters.
CURRENT - KEYWORD : DEFAULT
1 - number_of_runs : 1
2 - vib : 2
10 - thermal : 10
SYSTEMVERIFICATION - label : BURNIN
2 - min_lb_mode : 2
1 - tbr_passes : 1
1 - prt_on : 1
1 - cntmem_on : 1
1 - cmi_on : 1
1 - retention_on : 1
1 - cam_on : 1
1 - flt_passes : 50
1 - sta_passes : 25
1 - plb_nframes : 100
1 - txd_nframes : 50
1 - xpt_nframes : 200
1 - bpt_nframes : 20
1 - slk_nmegs : 50
1 - bpt_all_nframes : 30
1 - slk_all_nmegs : 50
systemverification: Arming the burnin run on switch 0.
systemverification: Starting burnin on Switch 0
systemverification: Monitoring progress of the burnin activity.
systemverification: Outputting Status
State Status Run Cmd TotCmds Script
COMPLETED PASS 1 22 22 switchburnin.sh
Diagnostics Each diagnostic test in this suit reports its own set of error messages when detecting a failure.
Refer to the Diagnostics section of individual diagnostic test help pages. These messages are
available only in the log file.
See Also burninErrClear, burninErrShow, burninStatus, diagSetCycle