Brocade Fabric OS Documentation Addendum v6.1.2_cee (53-1001216-01, June 2009)
102 Fabric OS Documentation Addendum
53-1001216-01
LLDP-DCBX configuration
5
7. In t h e Hello field, enter a time value in seconds. The Hello value sets the interval between hello
bridge protocol data units sent by the root switch configuration messages. The range is 4 to
180 seconds. The default is 30 seconds.
8. In the Multiplier field, set the number of consecutive misses allowed before LLDP considers
the interface to be down. The range is 1 to 10. The default is 4.The multiplier is related to the
Hello time interval. Using the defaults, you wait four times (the multiplier value) at 30 second
intervals (the hello value) before giving up on the interface.
9. In the FC0E Priority Bits field, type a value that indicates the desired user priority. Each bit
represents a user priority associated with FCoE traffic. The range is 0-255. The default is 8.
10. Choose the parameters you want to exchange. Note that the term TLV indicates packaging of
parameters into a Brocade-specific Type/Length/Value (TLV).
11. Click Apply.
12. Click Save Configuration.
Adding an LLDP profile
The LLDP profile determines LLDP settings per port.
1. Select the CEE tab on the Switch Administration panel.
2. Select the LLDP-DCBX tab.
3. Select the LLDP Profile tab (Figure 17).
FIGURE 17 CEE tab > LLDP-DCBX tab > LLDP Profile tab