Modifying FICON emulation
4
For a Brocade 7800 and FX8-24 blade, use the portShow fciptunnel command to determine the
FICON emulation settings. The following example show the FICON emulation settings for VE_Port
22 in slot 3:
sw1:FID79:admin> portshow fciptunnel 3/22
-------------------------------------------
Tunnel ID: 3/22
Tunnel Description:
Admin Status: Enabled
Oper Status: Up
Compression: On (Standard)
Fastwrite: On
Tape Acceleration: Write/Read
TPerf Option: Off
IPSec: Disabled
Remote WWN: Not Configured
Local WWN: 10:00:00:05:1e:45:3a:01
Peer WWN: 10:00:00:05:1e:39:fa:f3
Circuit Count: 10
Flags: 0x00000000
FICON: On
FICON XRC: On
FICON Tape Write: On
FICON Tape Read: On
FICON TinTir Emul: On
FICON Dvc Acking: On
FICON Read BLK-ID: On
Tape Write Pipe: 32
Tape Read Pipe: 32
Tape Write Devs: 16
Tape Read Devs: 16
Tape Write Timer: 300
Tape Max Chain: 3000000
FICON OXID Base: 0x8000
FICON Debug Flags: 0xf7c90010
Modifying FICON emulation
FICON emulation may be enabled on a per FCIP tunnel basis. For the Brocade 7500 switch and
FR4-18i blade you can use the portCfg ficon modify command to make modifications to the
feature. For the Brocade 7800 switch and FX8-24 blade, use the portCfg fciptunnel command to
make modifications to the emulation feature.
For details on command usage, refer to the Fabric OS Command Reference.
CAUTION
You will need to bring the FCIP tunnel down in order to make changes. This process is disruptive
to all traffic on the tunnel.
1. Connect to the switches at both ends of the FCIP tunnel and log in using an account assigned
to the admin role.
2. Disable the FCIP tunnel at both ends where the FICON emulation feature is enabled.