Brocade Fabric Watch Administrator's Guide v6.3.0 (53-1001342-01, July 2009)
46 Fabric Watch Administrator’s Guide
53-1001342-01
Threshold configuration
6
Threshold boundary level is setat : Default
DefaultCustom
Unit Percentage(%) Percentage(%)
Time base minuteminute
Low 0 0
High 100 100
BufSize 0 0
Threshold alarmlevel is set at: Default
Errlog-1, SnmpTrap-2, PortLogLock-4
RapiTrap-8, EmailAlert-16, PortFencing-32
Valid alarm matrix is 63
DefaultCustom
Changed 0 0
Below 0 0
Above 0 0
InBetween 0 0
1 : change behavior type 11 : change threshold alarm level
2 : change behavior interval 12 : change changed alarm
3 : change threshold boundary level 13 : change belowalarm
4 : change custom unit 14 : change abovealarm
5 : change custom timebase 15 : change inBetween alarm
6 : change custom low 16 : apply threshold alarm changes
7 : change custom high 17 : cancel threshold alarm changes
8 : change custom buffer 18 : return to previous page
9 : apply threshold boundary changes
10 : cancel threshold boundary changes
Select choice => : (1..18) [18]7
where:
2. Refer to the following system output to customize high threshold boundary for RXPerformance.
The threshold boundary section of the Advanced Configuration menu includes the threshold
information for the selected area. It contains two columns, Default (the default settings
column) and Custom (the custom settings column), and indicates the current setting.
NOTE
Default threshold boundary settings are Fabric OS default settings; custom settings are
user-defined.
Index A numeric identifier assigned to the element
ThresholdName A string identifier assigned to the element
BehaviorType Frequency of alarm notifications
BehaviorInt The element behavior interval, in seconds