Brocade Fabric Watch Administrator's Guide v6.3.0 (53-1001342-01, July 2009)

40 Fabric Watch Administrator’s Guide
53-1001342-01
Threshold configuration
6
PE - Protocol error
LR - Link reset
ST - State change
TU - Trunk utilization
-current_status Displays the selected port’s current threshold status.
-thresh_level Displays the threshold level (either default or custom).
-action_level Displays the alarms level (either default or custom).
--show Displays the threshold configuration for all configured VE_Ports.
ve-port Displays the port type to be configured as a VE_Port. Only a subset of areas
can be configured for this port type.
-area Displays the area to be configured on a VE_Port. Configurable areas for ports
of VE_Port type include the following:
UTIL - Port utilization
PKTLOSS - Packet loss
ST - State change
-current_status Displays the VE_Port’s current threshold status.
-thresh_level Specifies the threshold level (either default or custom).
-action_level Specifies the alarms level (either default or custom).
--set Configures the thresholds for monitoring a specified area for all ports of a
specified port type. When configuring a threshold, you must specify a port
type and an area.
port e_port - Configures thresholds for all E_Ports.
fop-port - Configures thresholds for all F_Ports.
Port - Configures thresholds for physical ports.
--area Configures the area monitored by the Fabric Watch daemon. The following
areas are valid when configuring or displaying thresholds on E_Ports,
FOP_Ports, and physical ports.
CRC - Cyclic redundancy check error
ITW - Invalid transmission word
C3TX_TO - Class 3 discards frames due to timeout (8 Gbps platforms only)
LOS - Loss of synchronization
LF - Link failure
RX - Receive error
TX - Transmit error
PE - Protocol error
LR - Link reset
ST - State change