Brocade Fabric Watch Administrator's Guide v6.3.0 (53-1001342-01, July 2009)

Fabric Watch Administrator’s Guide 95
53-1001342-01
Class default settings
B
Primitive Sequence
Protocol Error
Monitors the number
of primitive sequence
errors
Unit: Errors
Time Base: minute
Low: 0
High: 5
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Receive Performance Monitors the receive
rate, by percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
State Changes Monitors state
changes
Unit: Changes
Time Base: minute
Low: 0
High: 50
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Transmit (Tx)
Performance
Monitors the transmit
rate, by percentage
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
Packet Loss The number of
packets routed
through a port
exceeds the port
bandwidth.
Unit: Errors
Time Base: minute
Low: 0
High: 10
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Utilization The percent of
utilization for the port
at the time of the last
poll.
Unit: Errors
Time Base: minute
Low: 0
High: 100
Buffer:
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Out_of_range
In_range
Trunk Utilization The percent of
utilization for the
trunk at the time of
the last poll.
Unit: Percentage (%)
Time Base: minute
Low: 0
High: 100
Buffer: 0
Changed: 0
Below: 0
Above: 0
In-Between: 0
Informative
Informative
Informative
Informative
TABLE 21 E_Port class default settings (Continued)
Area Description Default threshold
settings
Default alarm settings Threshold state