Brocade Fabric Watch Administrator's Guide v6.3.0 (53-1001342-01, July 2009)
68 Fabric Watch Administrator’s Guide
53-1001342-01
Configuring advanced options
8
4. Type the number corresponding to the area that you want to configure, such as 6 for Invalid
CRCs.
1 : Link loss (E-Port)
2 : Sync loss (E-Port)
3 : Signal loss (E-Port)
4 : Protocol error (E-Port)
5 : Invalid words (E-Port)
6 : Invalid CRCS (E-Port)
7 : RXPerformance (E-Port)
8 : TXPerformance (E-Port)
9 : State Changes (E/VE-Port)
10 : Link reset (E-Port)
11 : Utilization (VE-Port)
12 : Packet Loss (VE-Port)
13 : C3 Discard (E-Port)
14 : Trunk Util
15 : return to previous page
Select an area => : (1..10) [10] 6
5. Fabric Watch displays a list of monitored elements in this area. The following sample output
shows the monitored elements in the Invalid CRCs menu area menu.
Index ThresholdName Port CurVal Status
LastEvent LasteventTime LastVal LastState
============================================================================
0 eportCRCs000 0 Error(s)/min enabled
started Tue Jun 2 12:05:07 2009 0 Error(s)/min Informative
where:
The area menu displays the following five options.
1 : refresh
2 : disable a threshold
3 : enable a threshold
4 : advanced configuration
5 : return to previous page
Select an area => : (1..10) [10] 4
6. Type the number 4, advanced configuration, for a list of advanced configuration options, which
are detailed in Table 12.
Index A numeric identifier assigned to the element.
ThresholdName A string identifier assigned to the element.
Port The user port number.
CurVal The current data value contained by the element.
Status Monitoring status, either enabled or disabled.
LastEvent The last event setting that triggered an event.
LasteventTime The timestamp of the last triggered event for the element.
LastVal The data value of the element at the time of the last event.
LastState The last detected state of the element.