HP StoreEver 1/8 G2 Tape Autoloader User and Service Guide (AK377-96024, December 2012)
• Events in the last 24 hours
• Events in the last 31 days
• Events older than 31 days
Set the Current Detail Level to see additional types of events:
• Normal will only show critical events or hard errors.
• More details will also show warning and configuration events.
• Everything shows all events.
Critical events are designated with a STOP sign icon. Expand the event for more information, as
shown in Figure 75 (page 107).
Figure 75 Critical event details
• The time stamp is in the format hours : minutes : seconds. The hours are in 24–hour clock
format. For example, in this case 14 is 2 p.m.
• The date is in the format year/month/day.
• The event ID is the number on the header line, 0x006E in this example. It uniquely maps to
an error code.
• HE designates a hard error. The STOP sign icon and the word Crit before the event ID also
indicate a hard error.
• The text description in the header (“robotic controller error” in this example) is the simple text
description of the main error code.
• The main error code (0x83) is displayed in parenthesis as the Global error code. The error
codes are described in “Main error codes” (page 108). The text after the main error code
(Robotic controller generic problem in this example) is the text description for the
error code.
• The error sub-code (0x02) is displayed in parenthesis as the Module error code. The error
sub-codes are described in “Error sub-code descriptions” (page 117). The text after the error
sub-code (Robotic: connection to slave robotic failed in this example) is name
of the component followed by the text description of the error sub-code.
• The Current command provides information for factory use only.
Error codes 107