HP StorageWorks 1/8 G2 Tape Autoloader firmware release notes Version 210 (AK377-96006, July 7, 2008)
Description
This release includes updated firmware for the HP StorageWorks 1/8 G2 Tape Autoloader.
The Autoloader firmware can be updated through any of the following methods:
• Remote management interface (RMI).
• Operator co
ntrol panel (OCP).
• HP Library and Tape Tools (L&TT).
Autoloader firmware version
• 2.1 0
Update recommendation Recommended
Supersedes All earlier versions of Autoloader firmw are.
Product models
All HP StorageWorks 1/8 G2 Tape Autoloaders.
Languages
• English (American)
• English (International)
Enhancements
• Support added for Internet Protocol version 6 (IPv6) .
• Support added for the 1/8 G2 and MSL Encryption Kit, which is a solution for generating and
storing encryption keys to write and restore encrypted data on LTO -4 media with LTO-4 tape drives.
• Support added for the Ultri um 1760 parallel SCSI half-height tape drive.
• Support added for SNMP version 2.
• Ability to save and restore the Autoloader configuration settings to a USB flash drive (from the
OCP) or a file (fr om the RMI).
Fixes
• Fixed a case where the Autoloader could appear unresponsive when used with network
security programs that constantly check the security status of all network por ts. Usually Drive
Commu
nication (code: F1 xx) errors were the last entries in the autoloader logs.
• Fixed a case where the Autoloader c ould appear unresponsive after the operator issued a
commandfromtheOCPtoremoveamagazinebutthemagazinewasnotremoved.
• Fixed
acasewherethetimestampintheautoloaderlogswouldberecordedasonedayearlier
than the Autoloader time.
• Fixed a case where error retry Code 88 00 (setting of sled motor parameters failed) was
inco
rrectly logged during the power up sequence.
• Fixed a case where error c ode 9B (sled position sensor not found) was reported at am bient
temperatures below 10 C when the mailslot did not pop out more than 15 mm.
• Fixe
d a case where the Autoloader would re port Not Ready after running the Demo Test.
• Improved an error message in the Wellness test when a corner slot is empty.
• The Autoloader temperature is now reported on LOG SENSE page 0x0D.
• Fix
edacasewheretheAutoloadercouldnotdetectwhenthemailslotwasclosedveryquickly.
HP StorageWorks 1/8 G2 Tape Autoloader firmware release notes