Hitachi Dynamic Link Manager Software Users Guide for Solaris (7.6)
Message
ID
Message Text Explanation
aa...aa: Error number that
indicates the executed processing
(decimal (base-10) number)
bb...bb: Return value of the
executed processing (decimal
(base-10) number)
Action
Make sure that sufficient free
capacity exists for the /var/tmp
directory. If the capacity is
insufficient, allocate the required
amount of capacity, and then retry
the operation. For details about
the required free capacity, see
Disk Capacity Requirements on
page 3-36 in Memory and Disk
Capacity Requirements on page
3-36.
KAPL09217
-E
An error occurred during reading
of the installation information
settings file. Error Code =
aa...aa,bb...bb
Details
An error occurred while reading
the installation information
settings file.
aa...aa: Error number (decimal
number) that specifies the
executed processing
bb...bb: Return value (decimal
number) of the executed
processing
Action
If the error code is 9001,-1:
You do not have read
permissions for the installation
information settings file. Make
sure that you have access
permissions.
If any other error code is output:
Contact your HDLM vendor or
the maintenance company if
there is a maintenance
contract for HDLM.
KAPL09218
-E
aa...aa cannot be executed. Details
A utility or command that
installhdlm uses was not in the
correct location, or you do not
have a required permission.
aa...aa: installhdlm_analysis,
dlnkmgr, or dlmsetconf
Action
Messages
8-71