Hitachi Dynamic Link Manager Software Users Guide for Solaris (7.6)
The path information is displayed only when a value is specified for the -
path -item parameter.
#2
This storage system applies when the dynamic I/O path control function is
disabled.
Table 6-13 Elements of a Path Name
Element Solaris representation
Corresponding
information
Host port number
(example: 0000)
Host port number A unique number in a host:
HDLM assigns this unique
number to each HBA port.
When two HBAs that have
two ports are installed on
the host, a value from 0000
to 0003 is assigned to each
port.
Bus number (example:
0000)
0 (fixed value) (Not applicable)
Target ID (example:
000000000000001A)
Target ID The target clause of the /
kernel/drv/sd.conf file.
Host LU number (example:
0005)
Logical unit ID or LUN The lun clause of the /
kernel/drv/sd.conf file.
Table 6-14 Product ID Displayed by the view -path Operation
Model names of storage
systems
Product ID
Without the -stname
parameter
With the -stname
parameter
(Displays the following
for the model ID)
Thunder 9500V Series
product identifier
#
9500V
Hitachi AMS2000/AMS
Series
AMS
Hitachi WMS Series WMS
Hitachi SMS Series SMS
HUS100 Series HUS100
Lightning 9900 Series
Emulation type
#
9910/9960
Lightning 9900V Series 9970/9980
• Hitachi NSC55
• Hitachi Universal
Storage Platform 100
• Hitachi Universal
Storage Platform 600
USP
6-52
Command Reference
Hitachi Dynamic Link Manager User Guide for Solaris
®