Message ID Message Text Explanation
Action
Specify a correct logical device file
name of an HDLM device, and
then re-execute the dlmcfgmgr
utility. For details on the
dlmcfgmgr
utility, see
dlmcfgmgr
Utility for Managing the HDLM
Configuration on page 7-22.
KAPL10322-E A file that defines HDLM-
unmanaged disks could not be
created. File name = aa...aa,
Errno = bb...bb. Execute the
DLMgetras utility to collect error
information, and then contact
your vendor or maintenance
company.
Details
Execution of the HDLM-
configuration definition utility
(dlmcfgmgr) failed because an
exclusion disk definition file
(aa...aa) could not be created.
aa...aa: File name
bb...bb: Error number (decimal
number)
Action
Execute the DLMgetras
utility for
collecting HDLM error information,
and then contact your HDLM
vendor or the maintenance
company if there is a maintenance
contract for HDLM.
For details on the DLMgetras
utility, see
DLMgetras Utility for
Collecting HDLM Error Information
on page 7-3.
KAPL10323-E The registration of the block
device driver for HDLM failed. All
dynamic major numbers are
exhausted. Unload (remove
from the kernel) an unnecessary
driver, and then execute the
dlmcfgmgr utility again.
Details
Registration of the block device
driver of HDLM failed because all
dynamic major numbers were
used.
Action
Unload (remove from the kernel)
any unnecessary driver, and then
re-execute the HDLM-
configuration definition utility
(dlmcfgmgr). For details on the
dlmcfgmgr
utility, see
dlmcfgmgr
Utility for Managing the HDLM
Configuration on page 7-22.
KAPL10324-I The device configuration of the
system has changed. Device =
aa...aa
Details
The device composition of a
system to a device (aa...aa) was
changed.
aa...aa: HDLM device name
Action
None.
8-80