User's Manual

Diagnostic Messages
X.25 Diagnostic Messages
Appendix C256
66 (CLEAR) Facility
parameter
not allowed.
Parameter field of a packet size
negotiation, window size negotiation or
throughput class negotiation facility in
a call setup packet has been found to
be invalid because it contains values
not allowed by the configured level
(1980 or 1984).
Parameter field of a packet size
negotiation, window size negotiation,
or throughput class negotiation facility
in a CALL ACCEPTED or CALL
CONFIRM packet has been found to be
invalid because it contains values
outside of the allowed range specified
by the configuration and previous call
setup packet.
For DDN configured interfaces, the
parameter field of the DDN standard
or DDN precedence facility in a call
setup packet has been found to be
invalid because it contains values not
allowed by the DDN X.25 Host
Interface Specification (BBN83).
67 (CLEAR) Invalid
called
address.
Unknown called address.
Called address contains a non-BCD
digit (i.e., a half byte with a value
other than 0 through 9).
68 (CLEAR) Invalid
calling
address.
Calling address contains a non-BCD
digit (i.e., a half byte with a value
other than 0 through 9).
Last digit of address field is not 0 and
the total number of digits present in
address field is odd.
Table C-5 Call Setup, Call Clearing, or Registration Problem (Continued)