Installation manual
FuelMaster
®
Installation Manual
103
CAUTION
If the Pedestal is mounted on an uneven surface and the screw
anchors are tightened, the welds at the base of the Pedestal may
be cracked. Washers, as spacers, should be installed on the screw
anchors under the corners of the Pedestal to account for minor
irregularities in the mounting surface, or to level the Pedestal.
ATTENTION
Si le piédestal est monté sur une surface raboteuse et les ancres
de vis sont serrées, les soudures à la base du piédestal peuvent
être rompues. Des écrous, comme mettredistance, peuvent être
installées sur les ancrages de vis sous les coins du piédestal pour
compenser des irrégularités mineures dans la surface de montage
concrète, ou pour niveler le piédestal.
6. Check the Pedestal mounts flush to the mounting surface
and is level. As required, install washers as needed under
the Pedestal for leveling.
7. Insert the screw anchors through the Pedestal mount holes
(and leveling washers) into the holes drilled into the
mounting surface.
8. Secure the Pedestal on the screw anchors with four screw
anchor nuts and washers.
9. Position the Pedestal Cover and Wiring Assembly up to the
Pedestal, then make the wire/cable connections with wire
nuts in accordance with Figure 4-27. Figure 4-27 depicts
wire colors that may not match the wire/cable in use. Note
the wire colors connected to J2, pins 1, 2, 4, and 5. These
wires must make specific pin connections to the I/O Silver
Board in the Master FMU.
10. Secure the Pedestal Cover and Wiring Assembly to the
Pedestal with four screws.
11. Attach the ground (green) lead to the Pedestal Cover and
Wiring Assembly ground screw.
12. Position the Cabinet up to the Pedestal Cover and Wiring
Assembly, and connect the Communication and Control
Harness connector and Power Harness connector to the
Cabinet Power Supply Board.
NOTE
If a gasket is not available, silicon sealant (RTV) may be used to
seal the Cabinet to the Pedestal. The Cabinet interface must be
sealed to prevent water intrusion.
13. Verify a gasket is installed between the Cabinet and
Pedestal, and attach the Cabinet to the Pedestal with fifteen
screws.
Wire Connections at Master FMU
The EIU is connected to the Master FMU the same as any
Satellite FMU connection. The Master FMU must be equipped
with a Satellite Option (STS part number 200034A) to accept the wire terminations and provide the
necessary internal interface cables. Master FMU-EIU connections may be hardwired with RS-422, or
wireless connected. The use of B&B Electronics Zlinx Radio Modems for a wireless connection is
Figure 4-28.
Connecting Wire
Harnesses
279