Installation manual

FuelMaster
®
Installation Manual
76
4) Connect one end of one wire to LD1 at the FMU, and the other end to hose 1 RESET FEED
in the dispenser.
5) (Using pump handle detection) Connect one end of the second wire to PHS1 at the FMU,
and the other end to hose 1 RESET COMPLETE in the dispenser.
6) (Using pump handle detection) Refer to Figure 4-6. Clip one leg of the resistor at R92 so
power cannot travel through the resistor. This action transfers pump handle detection from
LN1 to PHS1. If only one leg of the resistor is clipped, the resistor may be soldered back in
place, if needed.
7) Repeat steps 1 through 6, as required, for all additional hoses. When performing step 6, clip
one leg of the next resistor (R93 for hose 2, R94 for hose 3, etc.) for the next hose.
Figure 4-7. Wiring Diagram - Controlling Reset
252