Installation manual

4. FMU NEW INSTALLS. Repeat for each FMU. Note any deviations on page 5.
a. EXAMINATION OF PRODUCT
1) All equipment on packing list is accounted for.
2) Equipment matches customer requirement.
3) FMU is configured with correct number of hose positions and correct communications
boards are installed. Master FMU has internal communications cable.
4) FMU upper cabinet is correctly matched to pedestal.
5) Doors and locks operate freely.
6) No visible shipping damage.
b. PROVIDE TELEPROMPTING
1) Turn on FMU power switch. FMU initializes without error, and prompts the user to
INSERT KEY OR CARD TO BEGIN.
2) All FMU’s displayed an asterisk (*) to the left of the hose number and prompted, “HOSE
BUSY, SELECT ANOTHER…” when dispenser in use was selected from the FMU
keypad.
c. VALIDATE FMU ACCESS WITH PROKEE
®
, SMARTCARD, CREDIT CARD, AND/OR
KEYPAD
1) FMU’s validated authorized access by stepping to next menu prompt.
2) FMU’s rejected unauthorized access.
d. ACTIVATE PRODUCT DISPENSERS. All FMU’s successfully activate appropriate
dispensing hoses after authorized access.
e. VERIFY SINGLE HOSE AUTHORIZATION. Activate each hose (one hose at a time) in
automatic mode and verify no other hoses will dispense.
f. SIMULTANEOUS TRANSACTIONS. Each FMU allowed simultaneous operation of each
connected dispensing hose.
g. VERIFY NO COUNTS DURING DISPENSER RESET. Select COUNT TEST from the
Configuration Menu. Move Automatic/Manual Mode switches to Manual. Verify counts do not
register after the dispenser reset handle is activated. If counts do register, perform an
automated transaction for the applicable hose then query the FMU. Verify the quantity
observed in the query matches the quantity recorded at the dispenser. If quantities do not
match, a pulser with AC control must be installed. Repeat for each connected hose.
h. ENCODE, VERIFY, AND REVISE PROKEE
®
S OR SMARTCARDS
1) Prokee
®
s or Smartcards for test (if applicable), one for each available product, were
encoded and read data back correctly.
2) The Prokee
®
/Smartcard Encoder (if applicable) revised data and read data back
correctly.
i. PROVIDE FOR MANUAL OPERATION. Each FMU functioned normally while selected
dispensers were switched to manual operation. Dispensers switched to the manual position
did not show on the display as being available.
j. TRANSACTION HANDLING. Transactions for each hose, each day were assigned a
sequential four digit number starting with 0001.
k. DISABLE DISPENSER AFTER TRANSACTION. Repeat for multiple FMUs. Note any
deviations on page 5.
1) Each FMU disabled the applicable dispensers connected to it within the specified time
limits after dispensing was complete.
Page 2 of 5