Firmware Setup
:
NOTE
When an FMU is purchased for the TWO RELAYS PER PUMP option, there is no additional charge
for the additional hardware. If the option is added at a later date, the additional hardware must be
purchased at the current selling price.
Preset transaction limits may only be initiated in credit card transactions. Presets cannot be initiated
with a Prokee® or smartcard transaction.
To enable presets and W&M compliance, TWO RELAYS PER PUMP, SETPOINT, and PRINT DOLLAR
FOR PROKEE RECEIPTS must be enabled. Additional options which may be applicable for some are
DISPLAY PUMP PRICING, and RCPTS PRINT ON PWR UP. All options require either a laptop
connection to the FMU, or assistance from Syn-Tech’s Customer Satisfaction Center to enable the
necessary options. Perform the following when making a laptop connection:
Enable TWO RELAYS PER PUMP (required to enable presets):
1. After the abbreviation of the site name (e.g, FMU>), type a 59 command and press Enter. A display
similar to the following should appear:
CURRENT SYSTEM OPTIONS (MENU 1) CONFIGURATION
-----------------------------------------------------------------------------------
A. SYSTEM INPUT TYPE : VMN - VEH. KEY
B. CUSTOM SYSTEM OPTION : DISABLED
C. ENTERED VEHICLE IDs ARE : ALPHANUMERIC
D. SEMI MANUAL MODE : DISABLED
E. REAL GATE TXN : DISABLED
F. POWER FAIL CHECK : ENABLED
G. ENTERED USER IDs ARE : ALPHANUMERIC
H. FURNACE LOGGING : DISABLED
I. USING OLD PROKEES : DISABLED
J. SHOW PROKEE/SMARTCARD ID : DISABLED
K. CONFIRM PROKEE/SMARTCARD ID : DISABLED
L. DISPLAY PUMP PRICING : DISABLED
M. EIU PROKEE/SMARTCARD WHICH KEYS : NO KEYS!!!
N. TWO RELAYS PER PUMP : DISABLED
O. AUTO ACTIVATE SINGLE PUMP : DISABLED
P. MODEM CONNECT UPPER SPEED LIMIT : MAXIMUM
Q. RESTORE DEFAULT VALUES
USAGE - <LETTER>=CHANGE VALUE, <ESC>=EXIT
2. Press N. TWO RELAYS PER PUMP: DISABLED should reset to TWO RELAYS PER PUMP:
ENABLED.
3. Press Esc to exit. A display similar to the following should appear:
CONFIGURATION HAS CHANGED!
WOULD YOU LIKE TO SAVE IT ? (Y/N)
4. Press Y to save the configuration change. The following prompt will appear:
SAVING SYSTEM CONFIGURATION…
CONFIGURATION RECORDED.
316