Installation manual

Compatible
Electronic Require with
Mechanical/ Commercial/ Direct Dispenser Pulse Require DoD
Manufacturer/Model Electronic Retail Interface Interface* Option OINK* Note (see Notes)
Veeder-Root
EMR
3
Electronic Register Series
Electronic Commercial 8,20
Notes:
* Do not use OINKs in retail applications. Use the Electronic Dispenser Interface.
1. Requires two OINKs per hose: part number 226165 (divide by 4) or 226165A (divide by 1) for pulse and part number 226157 for control (used at Fort
Lewis, WA, with OINKS).
2. Controlled by master dispenser
3. Interfaced with 363M; required mod to dispenser by Maser to receive pulses.
4. Flowmeter has output shaft suitable for attaching mechanical pulser; problems with accuracy in a retail application at Chinhae, South Korea.
5. Attached mechanical pulser to totalizer shaft.
6. Requires 470 ohm, 1 watt, pull-up resistor for pulse connections.
7. Requires 330 ohm, 1 watt, pull-up resistor for pulse connections.
8. Requires 220 ohm, 1 watt, pull-up resistor for pulse connections.
9. Cannot fit pulser to any model other than 1820R
10. Some older models can be interfaced with OINK; newer models require PIE.
11. 785 may have to control neutral (w/o pump handle detection), or add 1/4 inch solenoid valves for pump handle detection. Have very little info on 793.
12. Requires part number 226521 (divide by 4) or 226521A (divide by 1) oink. Use Electronic Dispenser Interface in retail applications.
13. Requires part number 228648 (divide by 4) oink for commercial applications. Use Electronic Dispenser Interface in retail applications.
14. Requires part number 200158 oink. Use Electronic Dispenser Interface in retail applications.
15. Retail versions available as an optional upgrade.
16. Direct interface hasn't been tested; Gasboy specifies wiring option for E models. Not sure if available on other models of 8800. List of interface parts
provided by Gasboy for K models; list includes 12 required parts (14 for dual hose) not provided with dispensers without pulse option. Also learned there
is no Electronic Dispenser Interface Kit available.
17. Cannot separately control fast and slow valves for preset options; attempts to separately control will void warranty of new dispenser and result in
overrun.
18. Tokheim service and parts in the U.S. provided by Dresser Wayne.
19. END ONLY option necessary for pump handle detection; not presently available with DoD and classic systems.DoD and classic systems must
have pump handle detect set to NO.
20. Contact Syn-Tech Customer Satisfaction Center for pulser wiring instructions.
21. Wiring/setup instructions available in Product Bulletin 141.
22. Wiring/setup instructions available in Product Bulletin 142.
23. Wiring/setup instructions available in Product Bulletin 122.
24. Single hose applications only.
127
303