HP StorageWorks 9100c Extreme Data Storage System user guide (496784-001, November 2008)
Error codes
Table 4 Error codes
Error code
Description
Required actio
n
Cn01
Configuration error—Hardware not
supported
Log error, check hardware and cable
connections.
Fn00 – Fn67
Firmware error
Log error, restart enclosure. If error persists,
contact HP support.
Hn00 – Hn29
Hardware error—Controller error
Log error, contact HP support, replace
controller.
Hn30
Hardware error—Fatal ECC error
Log error, contact HP support, replace
cache module.
Hn31 – 6 6
Hardware er
ror—Controller error
Log error, contact HP support, replace
controller.
Hn67
Hardware error—SAS expander error
Log error, contact HP support, verify
cabling. If error persists, replace controller.
Fan module LEDs
Item
Descri
ption
Status
1
Fan module LED
Green—Normal operation
Blinking amber—Fan fault condition exists
Off—Fan unseated from connector or has failed
24