HP StorageWorks 9100c Extreme Data Storage System user guide (496784-001, November 2008)

The second character indicates the controller signalling the error:
1—Controller 1
2—Controller 2
The third and fourth characters indicate the specic error on the controller: (Displayed by pressing the up
or down arrow on the seven-segment display.)
Example 1. Error code example
C101 = Controller 1, unsupported conguration
POST codes
At power on, the enclosure goes through a series of tests called Power On Self Tests (POST). As each test
runs, a code is displayed on the seven-segment display indicating the current test being run.
Table 3 POST co
des
POST code
Description
SU
Controller rmware has been unpacked and launched.
S1
Port setup is complete.
S2
Pause / Wait for Expander Discovery is complete.
S3
Static Class Construction complete / Valid Stack Range has been set.
S4
PCI express c
ores have been initialized.
S5
PCI express core 0 link has been activated.
S6
Battery initialization complete.
S7
Memory Pools have been registered.
S8
The Serial Output Buffer initialization is complete.
S9
Product ID and controller ID have been set.
SA
OS Services object construction is complete.
SB
HCS initialization is complete.
SC
Task creation is complete.
9100c Extreme Data Storage System user guide
23