HP StorageWorks 9100 Extreme Data Storage System administration guide V1.0.2 (AN540-96018, February 2010)
10 Upgrading the HP ExDS9100
WARNING!
Before performing any of the procedures in this chapter, read the important warnings, precautions,
and safety information in Appendix D and Appendix E.
Adding new server blades
IMPORTANT:
Use only an HP ExDS9100-specific server blade. Do not try to install a standard server blade; otherwise,
the install server command fails with an invalid blade error message, and it will not boot.
The system software installed on a newly installed server blade is the original system software used
to install the existing server blades. If the exdsmgr install update command was used to install
additional or replacement RPMs, these RPMs are not installed on the new server blade. Use the
exds_rpmcheck program to determine which RPMs need to be installed. See Installing RPMs for
more information.
1. On the front of the blade chassis, in the next available server blade bay, remove the blank.
2. Prepare the server blade for installation.
9100 Extreme Data Storage System administration guide 95