HP StorageWorks 9100 Extreme Data Storage System administration guide V1.0.2 (AN540-96018, February 2010)

6 Viewing system status information
Several exdsmgr commands allow you to view the following information about the configuration
and status of your HP ExDS9100 Storage System:
Configuration, system, or status problems report
Server blade information
BladeSystem and interconnect details
Matrix state
Array information
LUN information
System information
Filesystem information
VNFS configuration details
HTTP service status information
Alert history information
Event logs
Firmware version information
Performance statistics
Syscheck command
The exdsmgr syscheck command gathers information from the system and presents a report if it
finds any problems. The problems are categorized under the following severities:
Critical ConditionsThe problem is critical to operation of the system and is causing, or has the
potential to cause, some or full failure of the system.
WarningsThe problem is serious, but the system can likely continue to operate.
The syscheck command reports problems on a fully installed and configured system. If you run
syscheck before the system is fully installed or configured, some of the errors reported might be
due to the incomplete state of the system. However, it is safe to run syscheck at any time. It takes
several minutes to run the syscheck command. HP recommends that you run the command regularly.
Syscheck report categories
Syscheck reports issues under the following categories:
SystemGeneral system issues
EnvironmentalIssues connected with power, temperature, status conditions
VhostsIssues connected with virtual hosts
iLoIssues connected with connectively to the iLO
PowerWhether all servers are powered on or not
ServerIssues connected to server status
9100 Extreme Data Storage System administration guide 41