HP StorageWorks 9100 Extreme Data Storage System administration guide V1.0.2 (AN540-96018, February 2010)
• T-15 Torx screwdriver
• 4-mm flat-blade screwdriver
• Phillips screwdriver
Additional documentation
The information in this section pertains to the specifics of the HP ExDS9100. For detailed component
replacement instructions, see the following documentation which is available at http://www.hp.com/
support/manuals:
• c7000 blade enclosure
• HP BladeSystem c7000 Enclosure Maintenance and Service Guide
• HP BladeSystem c-Class Enclosure Troubleshooting Guide
• Server blades
• HP ProLiant BL460c Server Blade Maintenance and Service Guide
• ExDS9100c
• HP StorageWorks ExDS9100c SAS controller cache module customer self repair instructions
• HP StorageWorks ExDS9100c SAS controller battery customer self repair instructions
• HP StorageWorks ExDS9100c SAS controller customer self repair instructions
• HP StorageWorks 3Gb SAS BL Switch Installation Instructions
• HP StorageWorks 3Gb SAS BL Switch Customer Self Repair Instructions
• ExDS9100cx
• HP StorageWorks 600 Modular Disk System Maintenance and Service Guide
Replacing the c7000 blade enclosure and server blade parts
NOTE:
This section contains information and procedures specific to the HP ExDS9100. For complete instructions
on the topics in this section, see the
HP BladeSystem c7000 Enclosure Maintenance and Service Guide
,
part number 413336-005.
Replacing the blade enclosure
This procedure assumes you have only changed the blade enclosure and that you transferred all
components from the original blade system (particularly, the OA modules and blades) to the new
blade enclosure.
IMPORTANT:
Make sure that you keep the same server blade bay numbers when moving blades from the old chassis
to the new chassis.
When you power up the blade enclosure, the HP ExDS9100 system does not boot. To make the
system work after swapping a blade enclosure, use the following procedure:
9100 Extreme Data Storage System administration guide 103