HP StoargeWorks ESL9000 series tape library user guide (April 2003)
Sense Data Values
132 HP StorageWorks ESL9000 Series Tape Library User Guide
0B 80 06 TRANSFER EMPTY - COMMAND ABORTED
Gripper does not contain cartridge at end of pick portion of MOVE
command.
Check location of cartridge used in operation.
Retry operation.
0B 80 0B COMMAND ABORTED BY USER
Informational message. No action is necessary.
0B 80 0D CARTRIDGE IS ONLY PARTIALLY GRIPPED (ONLY SEEN IN
THE FRONT SENSOR)
Issue a MOVE command to move the cartridge from the transfer element
to an empty storage element.
0B 80 10 LOAD RETRY FAILED
Library was unable to successfully load the drive, even after retries. Check
drive alignment. Reseat the drive. If the problem continues, drive might
need servicing.
0B 81 01 GRIPPER TIMEOUT
Gripper did not reach desired position.
0B 81 04 GRIPPER OPEN FAILURE
Gripper did not reach open position.
If this failure occurs after closing the door, or when the door is not
latched, then upgrade to the latest revision of firmware.
0B 81 05 GRIPPER CLOSE FAILURE
Gripper did not reach close position.
If this failure occurs after closing the door, or when the door is not
latched, then upgrade firmware to latest revision.
0B 81 51 UNABLE TO PICK CARTRIDGE
Cartridge was sensed in front gripper sensor, but was unable to seat
cartridge in the rear gripper sensor. Check that gripper sensors are
working and/or that tape was ejected far enough.
0B 82 04 ROTARY FRONT FAILED
The rotary move to the front position failed.
Retry the command.
Table 26: Sense Data Values (Hexadecimal) (Continued)
Sense