05 85 11 HORIZONTAL INVALID COMMAND
Horizontal axis commanded to position out of library mechanical limits.
Calibrate the library.
Upgrade firmware to latest revision.
If occurred when system was online, call your authorized service provider.
05 8A 02 UNCALIBRATED POSITION
Library requires calibration. Run a CALIBRATE ALL command.
05 8B 11 PASSTHRU INVALID COMMAND
Pass-through axis was commanded to a position out of the libraries
mechanical limits. Run a CALIBRATE ALL command.
05 F0 01 RESERVATION CONFLICT
Internal firmware error. Report this occurrence and previous command (if
known) to your HP service representative.
Upgrade firmware to the latest revision.
05 F1 00 COMMAND UNSPECIFIED
Internal firmware error. Report this occurrence and previous command (if
known) to your HP service representative.
Upgrade firmware to the latest revision.
05 F1 01 COMMAND HEAP OVERFLOW
Internal firmware error. Report this occurrence and previous command (if
known) to your HP service representative.
Upgrade firmware to the latest revision.
05 F1 02 UNRECOGNIZED COMMAND
Internal firmware error. Report this occurrence and previous command (if
known) to your HP service representative.
Upgrade firmware to the latest revision.
05 F1 03 COMMAND REGISTER ERROR
Internal firmware error. Report this occurrence and previous command (if
known) to your HP service representative.
Upgrade firmware to the latest revision.
05 F3 00 COMMUNICATION INTERNAL FAILURE
Internal drive communication port code or hardware failure. Reseat drive
module.
Table 26: Sense Data Values (Hexadecimal) (Continued)