Sense Data Values
120 HP StorageWorks ESL9000 Series Tape Library User Guide
04 80 0F LOW POWER ERROR
Check power connections, and check for failed power supplies.
04 80 11 MOTOR POWER FAILURE
Indicates motor power turned off for a reason not otherwise reported.
Toggle of the Stop button should clear.
If the motor power failure occurs after the action of closing the door, or
when the door is not latched, then upgrade firmware to latest revision.
Check door switches.
Check for one or more faulty Power Supply Modules.
04 80 23 BARCODE DECODER COMMUNICATION FAILURE
Unable to initialize decoder.Check cable connections around Y-axis
interconnect.
04 81 00 GRIPPER AXIS INTERNAL FAIL
Gripper axis code internal failure.
Contact your HP service representative.
04 81 54 GRIPPER TPU REGISTER FAILURE
Replace robotic controller board.
04 81 55 GRIPPER TPU RAM FAILURE
Replace robotic controller board.
04 82 00 ROTARY AXIS INERNAL FAIL
Upgrade firmware to latest revision.
Call your authorized service provider.
04 82 01 ROTARY TIMEOUT
The rotary axis did not reach the desired position within the time limit.
Retry the command. If the failure recurs, contact your authorized service
provider.
04 82 08 ROTARY HOME NOT FOUND
The home flag was not found. Run a CALIBRATE ALL command.
04 82 10 ROTARY INVALID START
The rotary axis has not been homed yet. Issue a CALIBRATE ALL
command.
Call your authorized service provider.
Upgrade firmware to latest revision.
Table 26: Sense Data Values (Hexadecimal) (Continued)
Sense