CLI Reference Guide

Figure 3-12 Cancel scan, Success response example
3.2.7 Reset Solution
Table 3-15 Reset Solution
?api=config&method=resetSolution
GET Description This function restores the solution as if it was newly installed on a clean device:
Removes all process data such as scanned files, pending jobs etc.
Restores default solution settings: Deactivates logs, removes icon, resets purge
settings and API passwords.
WARNING! Removing the solution button will cause all access control configuration
to be lost. Upon creating a new button, access will have to be reconfigured.
Authentication Requires basic authentication with device admin credentials.
Payload IN
OUT If 200, XML response with code 0
If 400, XML response with error code
Response Code 200 OK — success
400 Bad request:
Error code –10: Device is busy
Error code –12: Unexpected error
401 Unauthorized access – if basic authentication fails
500 Internal Server Error – if too many requests are active. Retry recommended.
Schema Request
Response
?api=common&rschema=default
Section 3.2 Configuration services 19