Administrator's Guide
Spare Part Number: 579229-001
Product Ver: 01
SHOW ENCLOSURE STATUS
Syntax
SHOW ENCLOSURE STATUS
Description
Displays the basic health and status of the enclosure and its subsystems. If the enclosure shows
degraded, the subsystem(s) causing the state change are detailed (for example, failed or missing
redundant module).
Restrictions
None
Example
SHOW ENCLOSURE STATUS
Enclosure:
Status: OK
Unit Identification LED: Off
Enclosure Manager:
Status: OK
Power Subsystem:
Status: OK
Power Mode: Power Supply Redundant
Power Capacity: 2400 Watts DC
Present Power: 454 Watts DC
Cooling Subsystem:
Status: OK
Fans Good/Wanted/Needed: 2/2/2
Fan 1: 4300 RPM (31%)
Fan 2: 6398 RPM (46%)
Server Subsystem
Status: OK
2 server blades installed, 2 powered on.
I/O Modules Subsystem:
Status: OK
SHOW ENCLOSURE TEMP
Syntax
SHOW ENCLOSURE TEMP
Description
Displays current status and reading of some of the thermal sensors in the enclosure. If the sensor
is unreadable due to absence of power or failure, ? is shown.
Restrictions
• Only integral measurements in Celsius are displayed (fraction, if any, is truncated).
• Not every sensor that is present in the enclosure is reported.
• For blades a ‘virtual ambient’ (not a physical) sensor temperature is shown that is computed
by iLO based on its thermal model and measurements from several sensors. This model is
opaque to EM. Until this calculation normalizes, 0 is shown as the temperature for the blade,
so that right after power on of the enclosure, it takes several seconds before a nonzero value
is shown for the blades while other sensors are reported immediately.
164 EMU reference