Administrator's Guide

3. Align the side rails and then push the replacement drive drawer partially back into the
messaging system enclosure until approximately 2 inches of the drawer is still out of the
enclosure.
CAUTION: Do not push the drive drawer completely into the enclosure. You must first connect
the power coil assembly to prevent damaging the power coil assembly.
4. Pull the cable slightly out of the coil power plug and connect it to the midplane board.
5. Reattach the coil power plug sheet metal bracket (1) and tighten the thumbscrew (2).
122 Removing and replacing hardware components