Administrator's Guide

ResolutionRoot cause
Type/
SeverityDescription
Error
Code
Ensure that connectivity between
the Enclosure Manager and the
The Enclosure Manager cannot
be reached from the server.
Error/
Critical
Enclosure Manager
Firmware Update Failed
0x1017
server is proper and then retry the
flash operation.
(EMU can't access
server's IP Address).
Check log files: %s and
%s.
You must diagnose the storage
enclosure and P1210m controller
Information about the hard disk
drives could not be retrieved prior
to flashing the storage.
Error/
Critical
Failed to retrieve HDD
information before
flashing %s using %s ,
0x1031
to obtain details of all attached
Please check the log file
(%s) for further details.
and available hard disk drives to
ensure the enclosure is in the OK
state.
Ensure that you have the supported
hardware configuration on
appliance.
The hard disk drive present on
the server or the enclosure is not
supported with the appliance.
Warning/
Normal
Flash not attempted for %s
using %s: Drive model(s)
not supported. Check log
0x1036
file (%s) for further
information.
Ensure that the cache board is
installed on the servers.
Flash was not attempted for
internal server hard disk drives
Information/
Normal
Flash not attempted for %s
using %s: P410i Smart
0x1037
because the P410i Smart ArrayArray Controller Cache
Controller cache board was notBoard is not present.
present. The cache board isCache board is needed
required to flash the internal
server hard disk drives.
to flash the internal server
HDD.
CMP 175